C++Instrument Catalog MFC 1.2
Metrolab C++InstrumentCatalog for MFC
|
PT2026 instrument class. More...
#include <PT2026.h>


Public Member Functions | |
| CPT2026Instrument (CVISAResourceManager &rRM, tResourceName Rsrc) | |
| Constructors / destructors. | |
| virtual | ~CPT2026Instrument () |
ErrorList | |
List containing detailed information about the last operation performed. | |
| const std::vector< sError > | ErrorList () |
| const sFwVersion & | FwVerInfo () |
| const sInstrInformation & | InstrumentInfo () |
Open / Close | |
Create a link to the instrument. The actual handle to the instrument is private to the class. | |
| bool | Connect (U32 InitialTimeout_ms) |
| void | Disconnect () |
Interface lock & unlock | |
Several communication ports are available on the instrument, including Ethernet that allows for remote control of the instrument. Locking a port will enforce the interface right to use get / set accessors to modify the behavior of the instrument whereas ports that don't have the lock are only allowed to read the instrument parameters. | |
| bool | LockInterface () |
| bool | UnlockInterface () |
Channels handling | |
The PT2026 allow several probes to be connected to it using either a probe multiplexer or a field camera adapter. | |
| bool | ChannelsGetList (MTL::SCPI::tChannelList &rChanList) |
| bool | ChannelsGetList (CExtendedChannelList &rChanList) |
| bool | ChannelsGetState (MTL::SCPI::tChannelList &rSelChanList, MTL::SCPI::tChannelList &rActiveChan) |
| bool | ChannelsSetLimitedListState (bool State) |
| bool | ChannelsGetLimitedListState (bool &rState) |
| bool | ChannelsSelect (const MTL::SCPI::tChannelList &rChanList) |
| bool | ChannelsGetInfo (const MTL::SCPI::tChannelList &rChanList, std::vector< sChannelIformation > &rChanInfo) |
| bool | ChannelsGetLimits (const MTL::SCPI::tChannelList &rChanList, std::vector< F64 > &rLowLimit_UNITS, std::vector< F64 > &rHighLimit_UNITS) |
| bool | ChannelGetRawHall (sProbeRawHall &rRawHall) |
| Returns the raw 16-bit ADC measurements performed by the hall sensor located at the tip of the NMR probe. Notice that all NMR probes aren't necessarily equipped with such sensor. Magnetic field cameras aren't equipped with such sensor. | |
| bool | ChannelGetHall (sProbeHall &rHall) |
| Returns in the current units the calibrated Hall measurements. | |
| bool | ChannelGetRemoteLEDMode (eRemoteBusyLEDmode &rMode) |
| bool | ChannelSetRemoteLEDMode (eRemoteBusyLEDmode Mode) |
Search parameters | |
An NMR measurement always starts with a search operation consisting in finding the NMR resonance. This search operation may take a very long time, especially with probe measuring high fields. To reduce the time taken by the search operation, one may lessen the search range. Failing to set the search range with respect to the actual magnetic field density that one tries to measure will result in an infinite search operation. The search range must be set to fit the probe dynamic range. If present, the Hall probe can be enabled allowing the search range to be set automatically. The search span set by the Hall subsystem will depend on the quality of the calibration. | |
| bool | ParmSearchSet (const sSearch< uParm > &rSearch, F64 Lgc0122_DetectionLevel_V=0.15) |
| Configure the search operation, including frequency steps and the search bounds specified in the selected unit. | |
| bool | ParmSearchGet (sSearch< uParm > &rSearch) |
| bool | ParmSearchGet (sSearch< sBoundedParm > &rSearch) |
| bool | ParmSearchSetManualValue (F64 ManualValue_UNITS) |
| Ask the instrument to perform a measurement at fixed frequency. Automatic search mode is left. | |
| bool | ParmSearchSetLimits (F64 LowLimit_UNITS, F64 HighLimit_UNITS) |
| Set the search bounds in the selected unit. | |
| bool | ParmSearchSetHallEnable (bool Enabled) |
| Allow the Hall probe to take control over the search range. | |
| bool | ParmSearchGetHallEnable (bool &rEnabled) |
Measure parameters | |
Accessors to configure the way the measurement is processed to compute the result. These accessors are very specific, it is recommended not to use them. | |
| bool | ParmMeasureSet (const sMeasure< uParm > &rMeasure) |
| bool | ParmMeasureGet (sMeasure< uParm > &rMeasure) |
| bool | ParmMeasureGet (sMeasure< sBoundedParm > &rMeasure) |
Averaging | |
An NMR measurement provided by the instrument can be the result of several measurements that are averaged. Two levels of averaging are available, one consists in averaging several NMR signals together using a repeat or exponential scheme and the other level consists in averaging NMR measurements using repeat, moving or exponential averaging. Be very careful using signal averaging as it may provide poor measurement results or even oscillation if used with a measured magnetic field density that isn't perfectly stable. As such, signal averaging isn't recommended and should be used only when confronted to stable but inhomogeneous conditions. | |
| bool | ParmAveragingSignalSet (const sSignalAveraging< uParm > &rSigAvg) |
| bool | ParmAveragingSignalGet (sSignalAveraging< uParm > &rSigAvg) |
| bool | ParmAveragingSignalGet (sSignalAveraging< sBoundedParm > &rSigAvg) |
| bool | ParmAveragingMeasurementSet (const sMeasurementAveraging< uParm > &rMeasAvg) |
| bool | ParmAveragingMeasurementGet (sMeasurementAveraging< uParm > &rMeasAvg) |
| bool | ParmAveragingMeasurementGet (sMeasurementAveraging< sBoundedParm > &rMeasAvg) |
Input trigger parameters | |
Configure the input trigger subsystem of the instrument. Use these methods to configure which event will latch a measurement. Available events are external trigger, internal timed trigger or continuous trigger. | |
| bool | ParmTriggerInputSet (const sInputTrigger< uParm > &rInputTrig) |
| bool | ParmTriggerInputGet (sInputTrigger< uParm > &rInputTrig) |
| bool | ParmTriggerInputGet (sInputTrigger< sBoundedParm > &rInputTrig) |
Output trigger parameters | |
Configures the output trigger subsystem of the instrument. Use these methods to specify the measured values that, when reached, must generate an external TTL level or edge. | |
| bool | ParmTriggerOutputSet (const sOutputTrigger< uParm > &rOutputTrig) |
| bool | ParmTriggerOutputGet (sOutputTrigger< uParm > &rOutputTrig) |
| bool | ParmTriggerOutputGet (sOutputTrigger< sBoundedParm > &rOutputTrig) |
RF Pulse parameters | |
Determines the rate and the width at which the sample is stimulated. The frequency of the pulse is not under the scope of these method that are just meant to determine the modulation rate. A simple modulation scheme is used, as for today, there is no way to generate other sequences (i.e spin echo, saturation inversion recovery, etc.) | |
| bool | ParmRFPulseSet (const sPulse< uParm > &rPulse) |
| bool | ParmRFPulseGet (sPulse< uParm > &rPulse) |
| bool | ParmRFPulseGet (sPulse< sBoundedParm > &rPulse) |
Digitization parameters | |
Configures the digitization subsystem. One may configure the dead-time (the duration during which the FID signal isn't sampled right after the RF burst that stimulate the NMR sample), the acquisition duration and the sampling rate. | |
| bool | ParmDigitizationSet (const sDigitization< uParm > &rDigitization) |
| bool | ParmDigitizationGet (sDigitization< uParm > &rDigitization) |
| bool | ParmDigitizationGet (sDigitization< sBoundedParm > &rDigitization) |
Matching / Tuning parameters | |
The NMR measuring head consists in a matched / tuned RLC circuit that needs to be set according to the operation frequency. These accessors are very specific and shouldn't be used. | |
| bool | ParmMatchingTuningSet (const sMatchingTuning< uParm > &rMatchingTuning) |
| bool | ParmMatchingTuningGet (sMatchingTuning< uParm > &rMatchingTuning) |
| bool | ParmMatchingTuningGet (sMatchingTuning< sBoundedParm > &rMatchingTuning) |
Units parameters | |
Determine the unit in which the measurements will be returned by the instrument. One may select Tesla, milli-Tesla, Gauss, Kilo-Gauss, MHz relative to the sample, MHz relative to the proton or ppm. For ppm units, one must state the reference value. Obviously, the reference must be set prior to set the units to ppm. Once the ppm unit is selected, getting the reference will return 0.0, being the exact difference to the reference. | |
| bool | ParmUnitsSet (eUnits Units) |
| bool | ParmUnitsSetPPMRef (tPPMReference_UNITS Ref) |
| bool | ParmUnitsGet (eUnits &rUnits, tPPMReference_UNITS &rRef) |
Reference Clock parameters | |
Sets the reference clock port direction. | |
| bool | ParmRefClockSet (eReferenceClock RefClock) |
| bool | ParmRefClockGet (eReferenceClock &rRefClock) |
Communication : USB | |
Enables or disables the USB communication port. | |
| bool | ParmComUsbSet (bool Enabled) |
| bool | ParmComUsbGet (bool &rEnabled) |
Communication : Ethernet | |
Enables or disables the Ethernet communication port. | |
| bool | ParmComEthernetSet (const sEthernet &rSettings) |
| bool | ParmComEthernetGet (sEthernet &rSettings) |
Communication : VXI11 | |
Enables or disables the VXI11 compatibility layer. | |
| bool | ParmComVXI11Set (bool Enabled) |
| bool | ParmComVXI11Get (bool &rEnabled) |
Settings / Files | |
| bool | ReadFileDirectory (U32 &rUsedBytes, U32 &rAvailableBytes, tFileList &rFileList) |
| bool | ReadFile (std::string Path, std::string &rContent) |
| bool | WriteFile (std::string Path, const std::string &rContent) |
| bool | DeleteFile (std::string Path) |
| bool | GetSettingFileList (std::vector< std::string > &rSettingFileList) |
| bool | SaveSettings (eSettingType Type, std::string Name) |
| bool | RecallSettings (std::string Name) |
Initiate / Abort / Trigger | |
Operation control of the measurement system. | |
| bool | Initiate (bool Continuous=false) |
| Starts the search operation and then immediately after NMR resonance detection proceed to NMR measurements. If no NMR resonance is found, the search operation is performed indefinitely. | |
| bool | Abort (bool CancelContinuous=true) |
| Abort the current operation (Search or measure). Once the operation is aborted, the instrument will be waiting to be initiated again. When aborted, only Hall measurement can be read. | |
| bool | SendBusTrigger () |
| Send a trigger to the instrument. If configured to react to this bus trigger, the acquisition sub system will collect a measurement and store it for future read out. | |
| bool | ForceOutputTrigger () |
| Set the output trigger according to current output trigger parametrization. This method is very specific and mainly present for debug purpose. | |
Measurements (data) gathering | |
| bool | MeasurementsGet (U32 NoMeasurements, std::vector< tFlux > &rFlux, eUnits &rUnits) |
| Returns the NMR magnetic field density measurements, including the unit used. A measurement vector is consistent to the unit. When a measurement was lost or failed for unknown reason, the value is substituted by NaN (Not A Number). | |
| bool | MeasurementsGet (U32 NoMeasurements, sArbitraryMeasurements ArbSelect, sAllMeasurements &rMeas, eUnits &rUnits) |
| Returns all the data associated to a measurement, including the temporal free induction decay, its FFT, the polynom that was computed to determine the location of the peak, the intermediate frequency, the estimated T2*. This method is very specific and mainly present for debug purpose. | |
| bool | GetSearchProgress (U8 &rSPR, F32 &rHallMeasurement_UNITS) |
| bool | SetFormat (eCommunicationFormat Format) |
| One can request the data in ASCII or binary format. The binary format, which needs extra operation to be decoded, are preferred as this format reduced the amount of data being sent on the communication link. Setting the format to either ASCII or binary won't affect the results gathered using the MeasurementsGet accessors. | |
Instrument Status Handling | |
See the user manual for a detailed explanation of the instrument status subsystem. | |
| bool | StatusPreset () |
| bool | StatusGet (sStatusRegister Reg, U16 &rStatus) |
| bool | StatusGet (std::vector< sStatusRegister > Regs, std::vector< U16 > &rStatus) |
| bool | StatusSetEnableRegister (eStatusRegisterSet Set, U16 DisableMask, U16 EnableMask) |
| bool | StatusSetTransitionFilter (eStatusRegisterSet Set, eTransition Transition, U16 ClearMask, U16 SetMask) |
| bool | StandardStatusSetEnableRegister (eStandardStatusRegister Set, U16 DisableMask, U16 EnableMask) |
Utilities | |
| bool | GetIdentification (std::string &rIdentification) |
| Returns the instrument identification string including its serial number and make. This string contains also the various electronic boards versions along the internal firmware and files versions. | |
| bool | GetSystemVersionAll (std::string &rSystVersion) |
| Returns all versions information (Hardware & Firmware) for the entire instrument. Available command with PT2026 Firmware >= 1.25 or with PT2026+. | |
| bool | PowerOff (bool Reboot=false) |
| Sending this command will shut the instrument down. Setting the reboot parameter to true will initiate a full shut-down and reboot of the instrument. Be careful, the link to the instrument is lost and must be re-acquired. It is a safe practice to release the instrument lock before performing to this operation. | |
| bool | Reset () |
| Calling this method will wipe out all user parameters that are stored in the file system and revert them back to factory defaults. | |
| bool | ReadCaseTemperature (F32 &rTemperatureDegC) |
| Returns the internal instrument temperature. An internal survey will shut the instrument down if this value reaches a temperature that is factory set to prevent the system to fail. The probe temperature isn't measured. | |
| bool | SwitchToDFUMode () |
| Restart the instrument in USB DFU mode, allowing the firmware to be upgraded. | |
| bool | ReadDebugLog (std::string &rDebugLog) |
| Returns a long string containing all the operations that were processed before the last proper instrument shut down. | |
| bool | ReadManufacturingDate (std::string &rSManufacturingDate, std::time_t &rManufacturingDate) |
| Returns the manufacturing date in plain text or a number representing the amount of seconds since 00:00, Jan 1 1970 UTC. | |
| bool | ReadCalibrationDate (std::string &rSCalibrationDate, std::time_t &rCalibrationDate) |
| Returns the calibration date in plain text or a number representing the amount of seconds since 00:00, Jan 1 1970 UTC. | |
| bool | SetCalibrationDate (std::string &rNewCalibrationDate) |
| Sets the new calibration date, given in YYMMDD format. | |
Low Level Utilities | |
| bool | DeviceROMRead (const MTL::SCPI::tChannel &rChannel, std::vector< U8 > &rROMContent) |
| bool | DeviceROMWrite (const MTL::SCPI::tChannel &rChannel, const std::vector< U8 > &rROMContent) |
| bool | NormalizationGet (const MTL::SCPI::tChannel &rChannel, tNormalizationTable &rNormalizationTable) |
| bool | NormalizationSet (const MTL::SCPI::tChannel &rChannel, const tNormalizationTable &rNormalizationTable) |
| bool | AuthenticationStatus (bool &rIsAuthenticated, std::string &rCipherMsgGet) |
| bool | AuthenticationRequest (const std::string &rCipherMsgSet, bool &rIsAuthenticated) |
| bool | LowLevelTransfer (const std::vector< U8 > &rDataToSend, std::vector< U8 > &rRcvdData, U8 &rReturnedStatus) |
| bool | WriteCustomCommand (const std::string &rWriteStr) |
| Public Member Functions inherited from MTL::Instrument::CVISAInstrument | |
| CVISAInstrument (CVISAResourceManager &rRM, tResourceName Rsrc) | |
| virtual | ~CVISAInstrument () |
| bool | Open (eOpenAccessMode AccessMode=eOpenAccessMode::NoLock, ViUInt32 Timeout_ms=0) |
| void | Close () |
| bool | IsOpen () |
| const ViStatus & | Status () |
| const ViSession & | Session () |
| bool | Write (const char *Str) |
| bool | Write (const std::string &rStr) |
| bool | Write (const CVISABuffer &rBuf) |
| bool | Write (const ViBuf WriteBuf, ViUInt32 BuffLen) |
| bool | Read (CVISABuffer &rBuf, bool Append=false) |
| bool | Read (ViPBuf ReadBuf, ViUInt32 ReadLen, ViUInt32 &rRetLen) |
| bool | SetTimeout (ViUInt32 Timeout) |
| bool | Clear () |
| bool | ReadSTB (ViUInt16 &rSTB) |
| bool | AssertTrigger (eTriggerProtocol Protocol) |
| bool | LockExclusive (ViUInt32 Timeout) |
| bool | LockShared (ViUInt32 Timeout, ViKeyId RequestedKey, ViChar AccessKey[]) |
| bool | Unlock () |
| bool | EnableEvent (eEventType Type, eEventMechanism Mechanism) |
| bool | DisableEvent (eEventType Type, eEventMechanism Mechanism) |
| bool | WaitOnEvent (eEventType Type, ViUInt32 Timeout) |
| bool | WaitOnAllEvents (ViUInt32 Timeout) |
| bool | DiscardEvents (eEventType Type, eEventMechanism Mechanism) |
| bool | GetAttribute (ViAttr Attribute, void *Value) |
| bool | UsbControlIn (ViInt16 bmRequestType, ViInt16 bRequest, ViUInt16 wValue, ViUInt16 wIndex, ViUInt16 wLength, ViPBuf buf, ViUInt16 &rretCnt) |
| bool | UsbControlOut (ViInt16 bmRequestType, ViInt16 bRequest, ViUInt16 wValue, ViUInt16 wIndex, ViUInt16 wLength, ViBuf buf) |
| bool | ConfigSerialPort (const sSerialPortSettings &rPortSettings) |
Additional Inherited Members | |
| Protected Attributes inherited from MTL::Instrument::CVISAInstrument | |
| CRecursiveMutex | m_Lock |
| CVISAResourceManager & | m_rRrsrcMan |
| tResourceName | m_Rsrc |
| ViSession | m_InstrSession |
| ViStatus | m_Status |
| CPT2026Instrument::CPT2026Instrument | ( | CVISAResourceManager & | rRM, |
| tResourceName | Rsrc ) |
Constructors / destructors.
Definition at line 244 of file PT2026.cpp.
|
virtual |
Definition at line 249 of file PT2026.cpp.
| bool CPT2026Instrument::Abort | ( | bool | CancelContinuous = true | ) |
Abort the current operation (Search or measure). Once the operation is aborted, the instrument will be waiting to be initiated again. When aborted, only Hall measurement can be read.
Definition at line 2783 of file PT2026.cpp.
| bool CPT2026Instrument::AuthenticationRequest | ( | const std::string & | rCipherMsgSet, |
| bool & | rIsAuthenticated ) |
Definition at line 3955 of file PT2026.cpp.
| bool CPT2026Instrument::AuthenticationStatus | ( | bool & | rIsAuthenticated, |
| std::string & | rCipherMsgGet ) |
Definition at line 3919 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelGetHall | ( | sProbeHall & | rHall | ) |
Returns in the current units the calibrated Hall measurements.
Definition at line 691 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelGetRawHall | ( | sProbeRawHall & | rRawHall | ) |
Returns the raw 16-bit ADC measurements performed by the hall sensor located at the tip of the NMR probe. Notice that all NMR probes aren't necessarily equipped with such sensor. Magnetic field cameras aren't equipped with such sensor.
Definition at line 662 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelGetRemoteLEDMode | ( | eRemoteBusyLEDmode & | rMode | ) |
Definition at line 720 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelSetRemoteLEDMode | ( | eRemoteBusyLEDmode | Mode | ) |
Definition at line 743 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsGetInfo | ( | const MTL::SCPI::tChannelList & | rChanList, |
| std::vector< sChannelIformation > & | rChanInfo ) |
Definition at line 545 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsGetLimitedListState | ( | bool & | rState | ) |
Definition at line 498 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsGetLimits | ( | const MTL::SCPI::tChannelList & | rChanList, |
| std::vector< F64 > & | rLowLimit_UNITS, | ||
| std::vector< F64 > & | rHighLimit_UNITS ) |
Definition at line 615 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsGetList | ( | CExtendedChannelList & | rChanList | ) |
Definition at line 422 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsGetList | ( | MTL::SCPI::tChannelList & | rChanList | ) |
Definition at line 398 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsGetState | ( | MTL::SCPI::tChannelList & | rSelChanList, |
| MTL::SCPI::tChannelList & | rActiveChan ) |
Definition at line 443 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsSelect | ( | const MTL::SCPI::tChannelList & | rChanList | ) |
Definition at line 524 of file PT2026.cpp.
| bool CPT2026Instrument::ChannelsSetLimitedListState | ( | bool | State | ) |
Definition at line 478 of file PT2026.cpp.
| bool CPT2026Instrument::Connect | ( | U32 | InitialTimeout_ms | ) |
Definition at line 283 of file PT2026.cpp.
| bool CPT2026Instrument::DeleteFile | ( | std::string | Path | ) |
Definition at line 2660 of file PT2026.cpp.
| bool CPT2026Instrument::DeviceROMRead | ( | const MTL::SCPI::tChannel & | rChannel, |
| std::vector< U8 > & | rROMContent ) |
Definition at line 3815 of file PT2026.cpp.
| bool CPT2026Instrument::DeviceROMWrite | ( | const MTL::SCPI::tChannel & | rChannel, |
| const std::vector< U8 > & | rROMContent ) |
Definition at line 3846 of file PT2026.cpp.
| void CPT2026Instrument::Disconnect | ( | ) |
Definition at line 344 of file PT2026.cpp.
| const std::vector< sError > CPT2026Instrument::ErrorList | ( | ) |
Definition at line 259 of file PT2026.cpp.
| bool CPT2026Instrument::ForceOutputTrigger | ( | ) |
Set the output trigger according to current output trigger parametrization. This method is very specific and mainly present for debug purpose.
Definition at line 2800 of file PT2026.cpp.
| const CPT2026Instrument::sFwVersion & CPT2026Instrument::FwVerInfo | ( | ) |
Definition at line 270 of file PT2026.cpp.
| bool CPT2026Instrument::GetIdentification | ( | std::string & | rIdentification | ) |
Returns the instrument identification string including its serial number and make. This string contains also the various electronic boards versions along the internal firmware and files versions.
Definition at line 3619 of file PT2026.cpp.
| bool CPT2026Instrument::GetSearchProgress | ( | U8 & | rSPR, |
| F32 & | rHallMeasurement_UNITS ) |
Definition at line 3225 of file PT2026.cpp.
| bool CPT2026Instrument::GetSettingFileList | ( | std::vector< std::string > & | rSettingFileList | ) |
Definition at line 2679 of file PT2026.cpp.
| bool CPT2026Instrument::GetSystemVersionAll | ( | std::string & | rSystVersion | ) |
Returns all versions information (Hardware & Firmware) for the entire instrument. Available command with PT2026 Firmware >= 1.25 or with PT2026+.
Definition at line 3641 of file PT2026.cpp.
| bool CPT2026Instrument::Initiate | ( | bool | Continuous = false | ) |
Starts the search operation and then immediately after NMR resonance detection proceed to NMR measurements. If no NMR resonance is found, the search operation is performed indefinitely.
Definition at line 2774 of file PT2026.cpp.
| const CPT2026Instrument::sInstrInformation & CPT2026Instrument::InstrumentInfo | ( | ) |
Definition at line 275 of file PT2026.cpp.
| bool CPT2026Instrument::LockInterface | ( | ) |
Definition at line 357 of file PT2026.cpp.
| bool CPT2026Instrument::LowLevelTransfer | ( | const std::vector< U8 > & | rDataToSend, |
| std::vector< U8 > & | rRcvdData, | ||
| U8 & | rReturnedStatus ) |
Definition at line 3983 of file PT2026.cpp.
| bool CPT2026Instrument::MeasurementsGet | ( | U32 | NoMeasurements, |
| sArbitraryMeasurements | ArbSelect, | ||
| sAllMeasurements & | rMeas, | ||
| eUnits & | rUnits ) |
Returns all the data associated to a measurement, including the temporal free induction decay, its FFT, the polynom that was computed to determine the location of the peak, the intermediate frequency, the estimated T2*. This method is very specific and mainly present for debug purpose.
Definition at line 2859 of file PT2026.cpp.
| bool CPT2026Instrument::MeasurementsGet | ( | U32 | NoMeasurements, |
| std::vector< tFlux > & | rFlux, | ||
| eUnits & | rUnits ) |
Returns the NMR magnetic field density measurements, including the unit used. A measurement vector is consistent to the unit. When a measurement was lost or failed for unknown reason, the value is substituted by NaN (Not A Number).
Definition at line 2812 of file PT2026.cpp.
| bool CPT2026Instrument::NormalizationGet | ( | const MTL::SCPI::tChannel & | rChannel, |
| tNormalizationTable & | rNormalizationTable ) |
Definition at line 3866 of file PT2026.cpp.
| bool CPT2026Instrument::NormalizationSet | ( | const MTL::SCPI::tChannel & | rChannel, |
| const tNormalizationTable & | rNormalizationTable ) |
Definition at line 3898 of file PT2026.cpp.
| bool CPT2026Instrument::ParmAveragingMeasurementGet | ( | sMeasurementAveraging< sBoundedParm > & | rMeasAvg | ) |
Definition at line 1414 of file PT2026.cpp.
| bool CPT2026Instrument::ParmAveragingMeasurementGet | ( | sMeasurementAveraging< uParm > & | rMeasAvg | ) |
Definition at line 1349 of file PT2026.cpp.
| bool CPT2026Instrument::ParmAveragingMeasurementSet | ( | const sMeasurementAveraging< uParm > & | rMeasAvg | ) |
Definition at line 1319 of file PT2026.cpp.
| bool CPT2026Instrument::ParmAveragingSignalGet | ( | sSignalAveraging< sBoundedParm > & | rSigAvg | ) |
Definition at line 1256 of file PT2026.cpp.
| bool CPT2026Instrument::ParmAveragingSignalGet | ( | sSignalAveraging< uParm > & | rSigAvg | ) |
Definition at line 1196 of file PT2026.cpp.
| bool CPT2026Instrument::ParmAveragingSignalSet | ( | const sSignalAveraging< uParm > & | rSigAvg | ) |
Definition at line 1170 of file PT2026.cpp.
| bool CPT2026Instrument::ParmComEthernetGet | ( | sEthernet & | rSettings | ) |
Definition at line 2404 of file PT2026.cpp.
| bool CPT2026Instrument::ParmComEthernetSet | ( | const sEthernet & | rSettings | ) |
Definition at line 2376 of file PT2026.cpp.
| bool CPT2026Instrument::ParmComUsbGet | ( | bool & | rEnabled | ) |
Definition at line 2349 of file PT2026.cpp.
| bool CPT2026Instrument::ParmComUsbSet | ( | bool | Enabled | ) |
Definition at line 2331 of file PT2026.cpp.
| bool CPT2026Instrument::ParmComVXI11Get | ( | bool & | rEnabled | ) |
Definition at line 2538 of file PT2026.cpp.
| bool CPT2026Instrument::ParmComVXI11Set | ( | bool | Enabled | ) |
Definition at line 2520 of file PT2026.cpp.
| bool CPT2026Instrument::ParmDigitizationGet | ( | sDigitization< sBoundedParm > & | rDigitization | ) |
Definition at line 2082 of file PT2026.cpp.
| bool CPT2026Instrument::ParmDigitizationGet | ( | sDigitization< uParm > & | rDigitization | ) |
Definition at line 2041 of file PT2026.cpp.
| bool CPT2026Instrument::ParmDigitizationSet | ( | const sDigitization< uParm > & | rDigitization | ) |
Definition at line 2017 of file PT2026.cpp.
| bool CPT2026Instrument::ParmMatchingTuningGet | ( | sMatchingTuning< sBoundedParm > & | rMatchingTuning | ) |
Definition at line 2191 of file PT2026.cpp.
| bool CPT2026Instrument::ParmMatchingTuningGet | ( | sMatchingTuning< uParm > & | rMatchingTuning | ) |
Definition at line 2153 of file PT2026.cpp.
| bool CPT2026Instrument::ParmMatchingTuningSet | ( | const sMatchingTuning< uParm > & | rMatchingTuning | ) |
Definition at line 2132 of file PT2026.cpp.
| bool CPT2026Instrument::ParmMeasureGet | ( | sMeasure< sBoundedParm > & | rMeasure | ) |
Definition at line 1087 of file PT2026.cpp.
Definition at line 1025 of file PT2026.cpp.
Definition at line 996 of file PT2026.cpp.
| bool CPT2026Instrument::ParmRefClockGet | ( | eReferenceClock & | rRefClock | ) |
Definition at line 2305 of file PT2026.cpp.
| bool CPT2026Instrument::ParmRefClockSet | ( | eReferenceClock | RefClock | ) |
Definition at line 2284 of file PT2026.cpp.
| bool CPT2026Instrument::ParmRFPulseGet | ( | sPulse< sBoundedParm > & | rPulse | ) |
Definition at line 1973 of file PT2026.cpp.
Definition at line 1935 of file PT2026.cpp.
Definition at line 1912 of file PT2026.cpp.
| bool CPT2026Instrument::ParmSearchGet | ( | sSearch< sBoundedParm > & | rSearch | ) |
Definition at line 863 of file PT2026.cpp.
Definition at line 796 of file PT2026.cpp.
| bool CPT2026Instrument::ParmSearchGetHallEnable | ( | bool & | rEnabled | ) |
Definition at line 971 of file PT2026.cpp.
| bool CPT2026Instrument::ParmSearchSet | ( | const sSearch< uParm > & | rSearch, |
| F64 | Lgc0122_DetectionLevel_V = 0.15 ) |
Configure the search operation, including frequency steps and the search bounds specified in the selected unit.
Definition at line 755 of file PT2026.cpp.
| bool CPT2026Instrument::ParmSearchSetHallEnable | ( | bool | Enabled | ) |
Allow the Hall probe to take control over the search range.
Definition at line 962 of file PT2026.cpp.
| bool CPT2026Instrument::ParmSearchSetLimits | ( | F64 | LowLimit_UNITS, |
| F64 | HighLimit_UNITS ) |
Set the search bounds in the selected unit.
Definition at line 951 of file PT2026.cpp.
| bool CPT2026Instrument::ParmSearchSetManualValue | ( | F64 | ManualValue_UNITS | ) |
Ask the instrument to perform a measurement at fixed frequency. Automatic search mode is left.
Definition at line 942 of file PT2026.cpp.
| bool CPT2026Instrument::ParmTriggerInputGet | ( | sInputTrigger< sBoundedParm > & | rInputTrig | ) |
Definition at line 1581 of file PT2026.cpp.
| bool CPT2026Instrument::ParmTriggerInputGet | ( | sInputTrigger< uParm > & | rInputTrig | ) |
Definition at line 1528 of file PT2026.cpp.
| bool CPT2026Instrument::ParmTriggerInputSet | ( | const sInputTrigger< uParm > & | rInputTrig | ) |
Definition at line 1481 of file PT2026.cpp.
| bool CPT2026Instrument::ParmTriggerOutputGet | ( | sOutputTrigger< sBoundedParm > & | rOutputTrig | ) |
Definition at line 1808 of file PT2026.cpp.
| bool CPT2026Instrument::ParmTriggerOutputGet | ( | sOutputTrigger< uParm > & | rOutputTrig | ) |
Definition at line 1713 of file PT2026.cpp.
| bool CPT2026Instrument::ParmTriggerOutputSet | ( | const sOutputTrigger< uParm > & | rOutputTrig | ) |
Definition at line 1640 of file PT2026.cpp.
| bool CPT2026Instrument::ParmUnitsGet | ( | eUnits & | rUnits, |
| tPPMReference_UNITS & | rRef ) |
Definition at line 2253 of file PT2026.cpp.
| bool CPT2026Instrument::ParmUnitsSet | ( | eUnits | Units | ) |
Definition at line 2235 of file PT2026.cpp.
| bool CPT2026Instrument::ParmUnitsSetPPMRef | ( | tPPMReference_UNITS | Ref | ) |
Definition at line 2244 of file PT2026.cpp.
| bool CPT2026Instrument::PowerOff | ( | bool | Reboot = false | ) |
Sending this command will shut the instrument down. Setting the reboot parameter to true will initiate a full shut-down and reboot of the instrument. Be careful, the link to the instrument is lost and must be re-acquired. It is a safe practice to release the instrument lock before performing to this operation.
Definition at line 3661 of file PT2026.cpp.
| bool CPT2026Instrument::ReadCalibrationDate | ( | std::string & | rSCalibrationDate, |
| std::time_t & | rCalibrationDate ) |
Returns the calibration date in plain text or a number representing the amount of seconds since 00:00, Jan 1 1970 UTC.
Definition at line 3757 of file PT2026.cpp.
| bool CPT2026Instrument::ReadCaseTemperature | ( | F32 & | rTemperatureDegC | ) |
Returns the internal instrument temperature. An internal survey will shut the instrument down if this value reaches a temperature that is factory set to prevent the system to fail. The probe temperature isn't measured.
Definition at line 3678 of file PT2026.cpp.
| bool CPT2026Instrument::ReadDebugLog | ( | std::string & | rDebugLog | ) |
Returns a long string containing all the operations that were processed before the last proper instrument shut down.
Definition at line 3705 of file PT2026.cpp.
| bool CPT2026Instrument::ReadFile | ( | std::string | Path, |
| std::string & | rContent ) |
Definition at line 2618 of file PT2026.cpp.
| bool CPT2026Instrument::ReadFileDirectory | ( | U32 & | rUsedBytes, |
| U32 & | rAvailableBytes, | ||
| tFileList & | rFileList ) |
Definition at line 2569 of file PT2026.cpp.
| bool CPT2026Instrument::ReadManufacturingDate | ( | std::string & | rSManufacturingDate, |
| std::time_t & | rManufacturingDate ) |
Returns the manufacturing date in plain text or a number representing the amount of seconds since 00:00, Jan 1 1970 UTC.
Definition at line 3725 of file PT2026.cpp.
| bool CPT2026Instrument::RecallSettings | ( | std::string | Name | ) |
Definition at line 2751 of file PT2026.cpp.
| bool CPT2026Instrument::Reset | ( | ) |
Calling this method will wipe out all user parameters that are stored in the file system and revert them back to factory defaults.
Definition at line 3671 of file PT2026.cpp.
| bool CPT2026Instrument::SaveSettings | ( | eSettingType | Type, |
| std::string | Name ) |
Definition at line 2707 of file PT2026.cpp.
| bool CPT2026Instrument::SendBusTrigger | ( | ) |
Send a trigger to the instrument. If configured to react to this bus trigger, the acquisition sub system will collect a measurement and store it for future read out.
Definition at line 2792 of file PT2026.cpp.
| bool CPT2026Instrument::SetCalibrationDate | ( | std::string & | rNewCalibrationDate | ) |
Sets the new calibration date, given in YYMMDD format.
Definition at line 3789 of file PT2026.cpp.
| bool CPT2026Instrument::SetFormat | ( | eCommunicationFormat | Format | ) |
One can request the data in ASCII or binary format. The binary format, which needs extra operation to be decoded, are preferred as this format reduced the amount of data being sent on the communication link. Setting the format to either ASCII or binary won't affect the results gathered using the MeasurementsGet accessors.
Definition at line 3269 of file PT2026.cpp.
| bool CPT2026Instrument::StandardStatusSetEnableRegister | ( | eStandardStatusRegister | Set, |
| U16 | DisableMask, | ||
| U16 | EnableMask ) |
Definition at line 3571 of file PT2026.cpp.
| bool CPT2026Instrument::StatusGet | ( | sStatusRegister | Reg, |
| U16 & | rStatus ) |
Definition at line 3302 of file PT2026.cpp.
| bool CPT2026Instrument::StatusGet | ( | std::vector< sStatusRegister > | Regs, |
| std::vector< U16 > & | rStatus ) |
Definition at line 3364 of file PT2026.cpp.
| bool CPT2026Instrument::StatusPreset | ( | ) |
Definition at line 3294 of file PT2026.cpp.
| bool CPT2026Instrument::StatusSetEnableRegister | ( | eStatusRegisterSet | Set, |
| U16 | DisableMask, | ||
| U16 | EnableMask ) |
Definition at line 3438 of file PT2026.cpp.
| bool CPT2026Instrument::StatusSetTransitionFilter | ( | eStatusRegisterSet | Set, |
| eTransition | Transition, | ||
| U16 | ClearMask, | ||
| U16 | SetMask ) |
Definition at line 3493 of file PT2026.cpp.
| bool CPT2026Instrument::SwitchToDFUMode | ( | ) |
Restart the instrument in USB DFU mode, allowing the firmware to be upgraded.
Definition at line 3698 of file PT2026.cpp.
| bool CPT2026Instrument::UnlockInterface | ( | ) |
Definition at line 377 of file PT2026.cpp.
| bool CPT2026Instrument::WriteCustomCommand | ( | const std::string & | rWriteStr | ) |
Definition at line 4014 of file PT2026.cpp.
| bool CPT2026Instrument::WriteFile | ( | std::string | Path, |
| const std::string & | rContent ) |
Definition at line 2639 of file PT2026.cpp.